Mein Dashboard


Mein Profil

Nutzen Sie unser Support Formular für eine zeitnahe Bearbeitung Ihres Anliegens.

SITRAIN Kundenberatung
Tel.: +49 (0)911-895-7575
E-Mail:

Leitfaden für die Registrierung (PDF download)


Um die Ansprechpartner für die Kursbuchung in Ihrer Region zu finden, klicken Sie bitte hier.

|
  1. Online-Training
  2. Antriebstechnik SINAMICS
  3. DR-GL15-DG - Beschreibung

Online-Training - SINAMICS GL150 - Diagnostics and Service (DR-GL15-DG)

Kurzbeschreibung

  • In this online course you will learn how the SINAMICS GL150 converter works. After the course you can carry out troubleshooting and recommissioning. For this purpose, you will also be able to back up data using the STARTER PC program.

Ziele

  • You are responsible for service work and maintenance of medium-voltage converters.
  • In this course you will learn how the SINAMICS GL150 converter works in the circuit technology of the load commutated current source inverters LCI. This course covers variable frequency drives VFD as well as starting frequency converters SFC.
  • After the course you will be able to read and understand operating parameters. In the event of a fault, you can carry out a target-oriented troubleshooting and recommissioning. For this purpose, you will also be able to back up data using the STARTER PC program.
Typ Online-Training
Dauer 5 Tage
Sprache en

Zielgruppe

  • Service personnel
  • Maintenance personnel

Inhalte

  • Design and function of the SINAMICS GL150:
    • Principle of a curent source inverter
    • Excitation equipment for the synchronous motor
    • Application as start-up frequency converter SFC
    • Application as static excitation equipment SEE
  • Operator Panel AOP30 and PC-Programm STARTER
  • Data backup:
    • Upload and download of parameter sets
    • Comparison of parameter sets
  • Reading and understanding circuit diagrams:
    • Input and output signals, setpoint channel
    • Control with CU320-2 and actual value measurements
    • Interface to PROFIBUS / PROFINET
  • Diagnostics and troubleshooting:
    • Checking the control and status signals
    • Analysis of alarm and error messages
    • Signal recording via trace function
  • Test functions after replacement of spare parts
  • Work safety on medium-voltage installations
  • Practical exercises on special remote training equipment

Teilnahmevoraussetzung

  •  
    • Knowledge of electrical drive technology
    • Knowledge of SINAMICS or STARTER is not required
    • Technical requirements

Hinweise

  • An introduction to the complete system and its operation under medium voltage (> 1000 V) is not covered by the course. This is usually done on site by personnel with the appropriate experience.

Downloads